Utah journeyman electrician exam: prep + the real requirements
What Utah actually requires
| Requirement | What the board says |
|---|---|
| License | Journeyman Electrician (state license); Residential Journeyman also exists |
| Experience required | 4-year apprenticeship program (576 classroom hours) + 8,000 licensed hours — OR 16,000 hours without the program. The exam-eligibility page (post-2025 rule) lists 6,000 hours for the school route; the apply page still says 8,000 — confirm with DOPL |
| Exam | Utah Journeyman written exam + practical exam (6 modules), through Prov |
| Application fee | $110 (all electrician classifications) |
| Renewal | 2-year cycle; 16 hours CE |
| Apprentice path | Utah licenses apprentices (no exam; supervision verification + $110) |
Report an error in Utah electrician exam factsEvery correction lands in the public changelog.
Practice set: 25 NEC questions
A cross-section of our 100-question NEC bank — general rules, branch circuits, grounding and bonding, services and calculations. Explanations cite the article each question tests, because the real exam is about knowing where the answer lives.
25 questions · Utah practice set. Pick an answer for each, then check. Explanations cite the rule each question tests.
1. The dedicated equipment space above a panelboard (to the structural ceiling or 6 ft) must be:
2. Tightening torque for terminal connections must be:
3. How many 20A small-appliance branch circuits are required to serve the kitchen/dining receptacles of a dwelling?
4. Conductors supplying a continuous load must have an ampacity of at least:
5. Which dwelling locations require GFCI protection for 125V receptacles?
6. Which of these is a standard overcurrent device rating?
7. Per the same table, 3 AWG copper at 75°C is rated:
8. The recommended maximum voltage drop for reasonable efficiency on a branch circuit (informational note) is:
9. AFCI protection is required for 120V, 15A and 20A branch circuits supplying:
10. Outdoor receptacles at grade level for a one-family dwelling are required:
11. A feeder supplying a dwelling unit's main panel from a 200A service disconnect located outside must be protected at:
12. Downstream of the service disconnect (e.g., in a subpanel), the grounded conductor must be:
13. The maximum grounding electrode conductor size ever required to a rod, pipe or plate electrode is:
14. The equipment grounding conductor for a 60A circuit (copper) is minimum:
15. Direct-buried nonmetallic conduit (PVC) generally requires a cover of:
16. In box-fill calculations, each 12 AWG conductor counts as:
17. When a raceway contains more than two conductors, the maximum fill is:
18. Metal boxes used with NM cable must be:
19. The grounding electrode conductor must be installed:
20. Overhead service-drop conductors over a residential driveway (not subject to truck traffic) require a vertical clearance of at least:
21. Each small-appliance and laundry circuit is added to the dwelling calculation at:
22. The demand load for one 12-kW household range is:
23. The maximum setting for an inverse-time circuit breaker providing short-circuit/ground-fault protection for a typical AC motor is:
24. Switches and circuit breakers must disconnect:
25. Receptacles installed outdoors in a wet location must have:
Then what?
Passed? Master requires 8,000 hours as a licensed journeyman (or degree routes). The full Utah ladder is on the entry-path page. See how to become an electrician in Utah for the full tier ladder, and the other topic tests on the electrician prep page.
Questions people actually ask
Does Utah license journeyman electricians?
Utah licenses journeyman electricians at the state level — apprenticeship classroom hours plus on-the-job hours, then a Prov written exam AND a practical exam.
Which NEC edition is on the exam?
The exam vendor's candidate bulletin for Utah names the tested edition — states adopt the NEC on their own cycle and sometimes amend it. Start from the board: Utah DOPL — Electrician Licensing Board.
Are these real exam questions?
No. Every question is original, written from the NEC's public article structure with the citation in the explanation — never from a real exam. See our methodology page.