Journeyman electrician practice tests
Your state's exam, verified from the board
Colorado · Utah · Florida · Arizona · Georgia — each page carries the board's own numbers with the date we read them, plus a 25-question practice set. More states as we verify their boards.
General & definitions
Article 90 (purpose/enforcement), Article 100 definitions, Article 110 installation requirements: working space, terminations, markings.
25 questions · General & definitions. Pick an answer for each, then check. Explanations cite the rule each question tests.
1. The stated purpose of the National Electrical Code is:
2. Who has the authority to interpret and enforce the NEC and to approve equipment and installations?
3. In the NEC, the word 'shall' indicates:
4. 'Ampacity' is defined as:
5. 'Readily accessible' means capable of being reached quickly:
6. A branch circuit is defined as the circuit conductors between:
7. A 'continuous load' is a load expected to run at maximum current for:
8. The minimum depth of clear working space in front of 120/240V electrical equipment likely to be worked on energized (Condition 1) is:
9. The minimum width of working space in front of electrical equipment is:
10. Unless the equipment is rated otherwise, conductor terminations for circuits of 100A or less are sized using which ampacity column?
11. In a 120/240V 3-phase 4-wire delta system, the conductor with the higher voltage to ground (high leg) must be identified with:
12. Service equipment in other than dwelling units must be legibly field-marked with:
13. Equipment interrupting rating must be:
14. Unused openings in boxes and enclosures (other than those designed for mounting) must be:
15. The grounded (neutral) conductor in sizes 6 AWG or smaller must be identified by:
16. An equipment grounding conductor with insulation must be colored:
17. A 'qualified person' is one who:
18. Circuit breakers and switches must be installed so the center of the operating handle, at its highest position, is not more than:
19. Illumination is required for working spaces around which equipment indoors?
20. The dedicated equipment space above a panelboard (to the structural ceiling or 6 ft) must be:
21. 'Listed' equipment is equipment:
22. Electrical equipment must be installed 'in a neat and workmanlike manner.' This enforceable requirement lives in:
23. Tightening torque for terminal connections must be:
24. A 'wet location' includes:
25. In a completed installation, each disconnecting means must be:
Branch circuits, conductors & OCPD
Articles 210/215 branch circuits and feeders, 240 overcurrent protection, 310 conductor ampacity, tap rules, GFCI/AFCI coverage.
25 questions · Branch circuits, conductors & OCPD. Pick an answer for each, then check. Explanations cite the rule each question tests.
1. How many 20A small-appliance branch circuits are required to serve the kitchen/dining receptacles of a dwelling?
2. The dwelling laundry area requires:
3. The dwelling bathroom receptacle circuit must be:
4. Conductors supplying a continuous load must have an ampacity of at least:
5. In dwelling habitable rooms, wall receptacles must be spaced so no point along the floor line (measured horizontally) is more than:
6. Kitchen countertop receptacles must be installed so no point along the wall line of the counter is more than:
7. Which dwelling locations require GFCI protection for 125V receptacles?
8. On a 20A branch circuit serving two or more receptacles, the receptacles may be rated:
9. Unless specifically permitted otherwise, the maximum overcurrent protection for 14, 12 and 10 AWG copper conductors is:
10. Which of these is a standard overcurrent device rating?
11. When the conductor ampacity does not match a standard OCPD rating, the next-higher standard device may protect it if:
12. Per the standard ampacity table (75°C column, copper), 8 AWG THWN is rated:
13. Per the same table, 3 AWG copper at 75°C is rated:
14. When 4 to 6 current-carrying conductors share a raceway, table ampacity must be adjusted to:
15. A neutral conductor is counted as a current-carrying conductor for adjustment purposes when:
16. The recommended maximum voltage drop for reasonable efficiency on a branch circuit (informational note) is:
17. A multiwire branch circuit must:
18. Using the 10-ft feeder tap rule, tap conductors must:
19. AFCI protection is required for 120V, 15A and 20A branch circuits supplying:
20. Overcurrent devices must not be located:
21. The rating of a single cord-and-plug-connected appliance on a branch circuit with other loads must not exceed:
22. Outdoor receptacles at grade level for a one-family dwelling are required:
23. Ungrounded (hot) conductors may be which colors?
24. Ampacity correction for ambient temperatures above 30°C (86°F) is applied by:
25. A feeder supplying a dwelling unit's main panel from a 200A service disconnect located outside must be protected at:
Grounding, bonding & wiring methods
Article 250 grounding and bonding, 300 wiring methods, 314 boxes and fill, cable and raceway support and burial depths.
25 questions · Grounding, bonding & wiring methods. Pick an answer for each, then check. Explanations cite the rule each question tests.
1. The purpose of bonding normally non-current-carrying metal parts is to:
2. The main bonding jumper connects:
3. Downstream of the service disconnect (e.g., in a subpanel), the grounded conductor must be:
4. For a service with 2/0 copper service-entrance conductors, the grounding electrode conductor (copper) must be at least:
5. A single rod electrode must be supplemented by an additional electrode unless it has a resistance to earth of:
6. The maximum grounding electrode conductor size ever required to a rod, pipe or plate electrode is:
7. A concrete-encased electrode (Ufer) consists of at least:
8. Metal underground water pipe used as an electrode must be in contact with earth for at least 10 ft and:
9. The equipment grounding conductor for a 60A circuit (copper) is minimum:
10. When circuit conductors are upsized for voltage drop, the equipment grounding conductor must be:
11. Direct-buried UF cable for a 120V, 20A GFCI-protected residential branch circuit requires a minimum cover of:
12. Direct-buried nonmetallic conduit (PVC) generally requires a cover of:
13. Where NM cable runs through bored holes in studs, the edge of the hole must be at least 1-1/4 in from the stud edge, or the cable must be protected by:
14. NM cable must be secured at intervals not exceeding ___ and within ___ of every box:
15. In box-fill calculations, each 12 AWG conductor counts as:
16. In the same calculation, a device (switch or receptacle) counts as:
17. EMT must be supported at least every ___ and within ___ of each box or termination:
18. When a raceway contains more than two conductors, the maximum fill is:
19. Conductor splices must be:
20. Where 4 AWG or larger conductors enter an enclosure, the entry must be protected by:
21. Metal boxes used with NM cable must be:
22. Bonding jumpers around concentric or eccentric knockouts are required:
23. An isolated-ground receptacle is identified by:
24. The grounding electrode conductor must be installed:
25. Where a metal raceway containing the GEC terminates, the raceway must be:
Services, motors & calculations
Article 230 services, 220 load calculations, 430 motors, 450 transformers, plus devices, pools, temporary power.
25 questions · Services, motors & calculations. Pick an answer for each, then check. Explanations cite the rule each question tests.
1. The minimum service disconnecting means rating for a one-family dwelling is:
2. Overhead service-drop conductors over a residential driveway (not subject to truck traffic) require a vertical clearance of at least:
3. One- and two-family dwellings require an emergency disconnect:
4. The general lighting load for a dwelling is calculated at:
5. Each small-appliance and laundry circuit is added to the dwelling calculation at:
6. Applying the general demand factors, the first 3,000 VA of general lighting/small-appliance load is taken at 100% and the remainder (to 120,000 VA) at:
7. A household electric clothes dryer is calculated at not less than:
8. The demand load for one 12-kW household range is:
9. Branch-circuit conductors for a single continuous-duty motor are sized at:
10. Motor running overload protection for a motor with a service factor of 1.15 is set at a maximum of:
11. The maximum setting for an inverse-time circuit breaker providing short-circuit/ground-fault protection for a typical AC motor is:
12. A motor disconnecting means must be:
13. Primary-only overcurrent protection for a 600V-class transformer rated more than 9A is set at a maximum of:
14. Switches and circuit breakers must disconnect:
15. A grounded (neutral) conductor must be provided at nearly all switch locations so that:
16. Receptacles in dwelling units must generally be:
17. Receptacles installed outdoors in a wet location must have:
18. Receptacles near a permanently installed pool (where permitted) must be located at least ___ from the inside pool wall, and at least one must be between that distance and 20 ft:
19. The equipotential bonding grid around a permanently installed pool uses solid copper not smaller than:
20. An air-conditioning condensing unit's disconnecting means must be:
21. For hermetic refrigerant motor-compressors, the branch-circuit OCPD is selected from:
22. On construction sites, GFCI protection is required for:
23. Using the 83% dwelling rule, the minimum copper service-entrance conductor for a 200A single-family dwelling service is:
24. Where a generator feeds a dwelling through a transfer switch for optional standby power, the transfer equipment must:
25. Conductors of different systems (e.g., 120/240V and Class 2 low voltage) in the same enclosure are:
Questions people actually ask
Is the journeyman exam open book?
In most states, yes — you bring (or are provided) the NEC and work time-limited questions against it. That changes how to study: memorizing answers loses to knowing WHERE each rule lives. Our explanations cite the article number for exactly that reason.
Which NEC edition will my exam use?
Whichever edition your state has adopted — states lag the newest edition by one or two cycles, and a few amend it. The exam vendor's candidate bulletin for your state names the tested edition; our state pages link the board that publishes it.
My state doesn't license journeyman electricians. What do I take?
Several states (Florida, Arizona, Georgia among our covered states) license electrical contractors at the state level and leave journeyman cards to counties or skip them entirely. The state pages below tell you which exam actually gates the work where you live — the NEC content is the study surface either way.
Are these real exam questions?
No — every question is original, written from the NEC's public article structure, never from a real exam or another provider's bank. See our methodology page.