Florida electrician exam: prep + the real requirements

Florida does NOT issue a state journeyman electrician license — journeyman cards are county/local. The state licenses electrical CONTRACTORS (certified statewide via a two-part Pearson VUE exam). The facts below come from Florida DBPR — Electrical Contractors' Licensing Board (ECLB)'s own pages, read Aug 28, 2026 — with a free 25-question NEC practice set underneath.

What Florida actually requires

Read from Florida DBPR — Electrical Contractors' Licensing Board (ECLB) on Aug 28, 2026. Boards change fees and rules — always confirm on the board page before applying.
RequirementWhat the board says
State licensesCertified/Registered Electrical Contractor only — the board's own FAQ: it licenses contractors, not electricians
Journeyman cardIssued by county/local jurisdictions, typically NEC-based exams — check your county's requirements
State contractor examTwo parts (technical/safety + business), computer-based via Pearson VUE; scores valid 3 years at application
Contractor experienceMust include at least 40% of work in 3-phase services (one of several routes in the application instructions)
Financial requirementsCredit report + financial statement showing net worth of at least $10,000
RenewalCertified $296 / Registered $121; expires 8/31 of EVEN years; 11 CE hours

Report an error in Florida electrician exam factsEvery correction lands in the public changelog.

Practice set: 25 NEC questions

A cross-section of our 100-question NEC bank — general rules, branch circuits, grounding and bonding, services and calculations. Explanations cite the article each question tests, because the real exam is about knowing where the answer lives.

25 questions · Florida practice set. Pick an answer for each, then check. Explanations cite the rule each question tests.

  1. 1. When 4 to 6 current-carrying conductors share a raceway, table ampacity must be adjusted to:

  2. 2. A multiwire branch circuit must:

  3. 3. Overcurrent devices must not be located:

  4. 4. Ungrounded (hot) conductors may be which colors?

  5. 5. The purpose of bonding normally non-current-carrying metal parts is to:

  6. 6. For a service with 2/0 copper service-entrance conductors, the grounding electrode conductor (copper) must be at least:

  7. 7. A concrete-encased electrode (Ufer) consists of at least:

  8. 8. When circuit conductors are upsized for voltage drop, the equipment grounding conductor must be:

  9. 9. Where NM cable runs through bored holes in studs, the edge of the hole must be at least 1-1/4 in from the stud edge, or the cable must be protected by:

  10. 10. In the same calculation, a device (switch or receptacle) counts as:

  11. 11. Conductor splices must be:

  12. 12. Bonding jumpers around concentric or eccentric knockouts are required:

  13. 13. Where a metal raceway containing the GEC terminates, the raceway must be:

  14. 14. One- and two-family dwellings require an emergency disconnect:

  15. 15. Applying the general demand factors, the first 3,000 VA of general lighting/small-appliance load is taken at 100% and the remainder (to 120,000 VA) at:

  16. 16. Branch-circuit conductors for a single continuous-duty motor are sized at:

  17. 17. A motor disconnecting means must be:

  18. 18. A grounded (neutral) conductor must be provided at nearly all switch locations so that:

  19. 19. Receptacles near a permanently installed pool (where permitted) must be located at least ___ from the inside pool wall, and at least one must be between that distance and 20 ft:

  20. 20. For hermetic refrigerant motor-compressors, the branch-circuit OCPD is selected from:

  21. 21. Where a generator feeds a dwelling through a transfer switch for optional standby power, the transfer equipment must:

  22. 22. Who has the authority to interpret and enforce the NEC and to approve equipment and installations?

  23. 23. 'Readily accessible' means capable of being reached quickly:

  24. 24. The minimum depth of clear working space in front of 120/240V electrical equipment likely to be worked on energized (Condition 1) is:

  25. 25. In a 120/240V 3-phase 4-wire delta system, the conductor with the higher voltage to ground (high leg) must be identified with:

Then what?

The NEC practice below still applies — Florida's local journeyman exams and the state contractor technical exam are code-based. Your county's exam bulletin names the tested NEC edition. See how to become an electrician in Florida for the full tier ladder, and the other topic tests on the electrician prep page.

Questions people actually ask

Does Florida license journeyman electricians?

Florida does NOT issue a state journeyman electrician license — journeyman cards are county/local. The state licenses electrical CONTRACTORS (certified statewide via a two-part Pearson VUE exam).

Which NEC edition is on the exam?

The exam vendor's candidate bulletin for Florida names the tested edition — states adopt the NEC on their own cycle and sometimes amend it. Start from the board: Florida DBPR — Electrical Contractors' Licensing Board (ECLB).

Are these real exam questions?

No. Every question is original, written from the NEC's public article structure with the citation in the explanation — never from a real exam. See our methodology page.