EPA 608 Type II — high-pressure: free practice test

High- and very-high-pressure appliances (residential split systems, most commercial AC and refrigeration): leak repair thresholds, evacuation levels, recovery techniques. The real section is 25 questions; you need 18 (72%). 25 original questions below, each explained with the rule it tests.

25 questions · Type II — high-pressure. Pick an answer for each, then check. Explanations cite the rule each question tests.

  1. 1. A high-pressure appliance uses a refrigerant with a boiling point between:

  2. 2. For a high-pressure appliance with more than 200 lb of charge using recovery equipment made after 11/15/1993, the required evacuation level is:

  3. 3. For an HCFC-22 appliance of 200 lb or less, the required evacuation level (post-1993 equipment) is:

  4. 4. If the system will be opened for a minor repair and leaks would prevent reaching the required vacuum, you may evacuate to:

  5. 5. Which recovery method removes refrigerant fastest from a large high-pressure system?

  6. 6. Under the 2016 amendments (as modified in 2020), commercial refrigeration appliances with 50 lb or more of ozone-depleting refrigerant must have leaks repaired when the annual leak rate exceeds:

  7. 7. Comfort-cooling appliances (50 lb+ ODS) must be repaired when the leak rate exceeds:

  8. 8. The pressure-temperature relationship is used in Type II work to:

  9. 9. Before charging a system that has been open to the atmosphere, the technician should:

  10. 10. Which is a safe practice when recovering from a system with a burned-out hermetic compressor?

  11. 11. Refrigerant leaving the appliance as a liquid during recovery should be routed so that:

  12. 12. Which component must be replaced when a system is opened and moisture may have entered?

  13. 13. For appliances with 50 lb or more of ozone-depleting refrigerant, once a leak above the applicable threshold is discovered, repairs generally must be completed within:

  14. 14. After repairing a leak on a 50+ lb ODS appliance, the technician must perform:

  15. 15. Speeding up recovery from a large high-pressure system is legitimately done by:

  16. 16. Recovery equipment used on high-pressure appliances must be certified by an EPA-approved organization and must be:

  17. 17. A technician measures cylinder pressure well above the P/T chart value for the labeled refrigerant at the measured temperature. The correct action is:

  18. 18. When a system's liquid line filter-drier has a sight glass with a moisture indicator showing 'wet', the technician should:

  19. 19. In a system with a receiver, the fastest legitimate way to remove most of the charge before a low-side repair is:

  20. 20. Which gauge-manifold practice avoids mixing refrigerants between jobs?

  21. 21. An open (non-hermetic) compressor that has sat unused for months most commonly leaks at:

  22. 22. Where must refrigerant vapor be drawn from to complete recovery after liquid has been removed by push-pull?

  23. 23. Evacuating a system to 500 microns and watching the micron gauge rise quickly to a plateau then hold indicates:

  24. 24. The sight glass in the liquid line bubbles continuously at steady load. Among refrigerant-side causes, this most commonly indicates:

  25. 25. When retrofitting an R-22 system to a 400-series HFC blend, which step is required for reliable operation?

Other sections: CoreType I — small appliancesType III — low-pressure · Certifier finder · All prep