EPA 608 Type I — small appliances: free practice test

Appliances with 5 lb or less of refrigerant, factory-charged and hermetically sealed: domestic refrigerators, window units, dehumidifiers. Recovery requirements for small appliances. The real section is 25 questions; you need 18 (72%). 25 original questions below, each explained with the rule it tests.

25 questions · Type I — small appliances. Pick an answer for each, then check. Explanations cite the rule each question tests.

  1. 1. A Type I appliance contains no more than how much refrigerant?

  2. 2. When recovering from a small appliance with a working compressor using recovery equipment made after November 15, 1993, you must recover:

  3. 3. If the compressor of a small appliance is not operating, the required recovery is:

  4. 4. Passive recovery on a small appliance is also called:

  5. 5. A piercing-type access valve should be:

  6. 6. Which technique helps recover more refrigerant from a small appliance whose compressor is not running?

  7. 7. Recovery equipment for small appliances must be certified by:

  8. 8. Type I certification allows work on which of the following?

  9. 9. Refrigerant recovered from a small appliance may be returned to the same appliance or another owned by the same person:

  10. 10. Nitrogen may be used to pressurize a system for leak testing if:

  11. 11. The typical charge of a household refrigerator is closest to:

  12. 12. Before beginning recovery from a small appliance, the technician should verify the appliance's charge by:

  13. 13. When using a system-dependent recovery process on a small appliance with an operating compressor, refrigerant is typically captured in:

  14. 14. Recovery from a small appliance is considered complete under the 4 in Hg standard when:

  15. 15. The sale of small cans of substitute refrigerant (2 lb or less, e.g. for MVAC top-off) to non-certified persons is:

  16. 16. A solderless piercing valve is best suited to:

  17. 17. If a small appliance's compressor does not run and the technician uses a self-contained (active) recovery unit, the required recovery level is:

  18. 18. Recovered refrigerant that will be reused in the SAME owner's equipment:

  19. 19. Which condition makes recovery from a small appliance faster?

  20. 20. The DOT classification/label required when shipping a filled refrigerant recovery cylinder is:

  21. 21. Before transferring refrigerant into a recovery cylinder, the technician must confirm the cylinder:

  22. 22. A small appliance sealed system that reads 0 psig before recovery most likely:

  23. 23. Persons servicing small appliances for disposal (e.g., a scrap yard receiving refrigerators) must either recover the refrigerant themselves or:

  24. 24. Excess refrigerant vapor left in a recovery hose when disconnecting is minimized by:

  25. 25. When pressurizing a dead small-appliance system to find a leak, the safest gas and method is:

Other sections: CoreType II — high-pressureType III — low-pressure · Certifier finder · All prep